Parameter Write Inhibit Status / Par_Write Inhib St; First Infeed Commissioning / First Inf_Comm - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

725:
740:
745:
750:
800:
10050: Wait for synchronization
10100: Wait for CU LINK slaves
10150: Wait until actual topology determined
10200: Evaluation component status
10250: Call conversion functions for parameter
10300: Preparation cyclic operation
10350: Autom. FW update DRIVE-CLiQ components
10400: Wait for slave properties
10450: Check CX/NX status
10500: Wait until DRIVE-CLiQ cyclic
10550: Carry out warm start
10600: Evaluate, encoder status
10800: Partial boot completed
Index:
[0] = System
[1] = Partial boot
r3996[0...1]

Parameter write inhibit status / Par_write inhib st

All objects
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays whether writing to parameters is inhibited.
r3996[0] = 0:
Parameter write not inhibited.
0 < r3996[0] < 100:
Parameter write inhibited. The value shows how the calculations are progressing.
Index:
[0] = Progress calculations
[1] = Cause
Note:
Re index 1:
Only for internal Siemens troubleshooting.
r3998

First infeed commissioning / First inf_comm

B_INF
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
0
Description:
Displays whether the infeed must be commissioned for the first time.
0 = Yes
2 = No
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Wait until DRIVE-CLiQ cyclic
Check the ability to operate
Start of the time slices
Interrupt enable
Initialization finished
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
65535
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
599

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents