Friction Characteristic Value N0 / Friction N0; Friction Characteristic Value N1 / Friction N1; Friction Characteristic Value N2 / Friction N2; Friction Characteristic Value N3 / Friction N3 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p3820[0...n]

Friction characteristic value n0 / Friction n0

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 1st value pair of the friction characteristic.
Dependency:
Refer to: p3830, p3845
p3821[0...n]

Friction characteristic value n1 / Friction n1

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 2nd value pair of the friction characteristic.
Dependency:
Refer to: p3831, p3845
p3822[0...n]

Friction characteristic value n2 / Friction n2

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 3rd value pair of the friction characteristic.
Dependency:
Refer to: p3832, p3845
p3823[0...n]

Friction characteristic value n3 / Friction n3

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 4th value pair of the friction characteristic.
Dependency:
Refer to: p3833, p3845
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
15.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
30.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
60.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
120.00 [rpm]
581