Test Pulse Evaluation Status / Test Puls Ev Stat; Parameter Tuning Selection / Par Tuning Select; Motor Data Identification Control Word / Motid Stw - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r1902

Test pulse evaluation status / Test puls ev stat

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the status of the test pulse evaluation.
Bit field:
Bit
00
01
02
03
04
Note:
If the ground fault test was selected, but not successfully performed, then sufficient current will not be able to be
established during the test pulses.
Re bit 04:
A test pulse longer than one sampling time has occurred
p1905

Parameter tuning selection / Par tuning select

VECTOR_G (n/M)
Can be changed: C2(1), T
Data type: Integer16
P-Group: Motor identification
Not for motor type: -
Min
0
Description:
The fine encoder calibration should be started during the first commissioning or after the encoder is replaced.
The fine calibration starts when the pulses are enabled and performs a rotating measurement (approximately 1
minute). In this case, a setpoint speed of at least 40 % of the motor rated speed must be entered, and the torque
must be less than half of the motor rated torque.
The phases of the fine calibration of displayed using alarm A07976.
The fine calibration ends with the calculation of p0431 for the following pulse inhibit.
p1905 is automatically set to 0 at the end of the fine calibration.
Value:
0:
90:
Dependency:
If the motor encoder adjustment has not been performed (p3925.4 = 0) or the encoder calibration is activated (p1990
!= 0), then encoder fine calibration is prevented.
Refer to: p1272, p1910, p1960, p1990
Notice:
During encoder fine calibration, the motor must be operated without a load - and if a motor holding brake is being
used, this must be opened.
Note:
For p1905 = 90 and with the pulses not enabled, the function is only executed the next time that the pulses are
enabled.
When selecting the encoder fine calibration, the changeover of the motor data sets is suppressed.
p1909[0...n]

Motor data identification control word / MotID STW

VECTOR_G
Can be changed: T
Data type: Unsigned32
P-Group: Motor identification
Not for motor type: -
Min
-
Description:
Sets the configuration for the motor data identification.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Short-circuit test successfully performed
Phase short-circuit detected
Ground fault test successfully performed
Ground fault detected
Identification pulse width greater than the
minimum pulse width
Inactive
Fine encoder calibration
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
90
Calculated: CALC_MOD_ALL
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
FP
-
-
-
-
-
443