r7051[0...n]

Par_circuit circulating current phase V / Circ_I_phase V

VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the circulating current of phase V as peak value.
r7052[0...n]

Par_circuit circulating current phase W / Circ_I_phase W

VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the circulating current of phase W as peak value.
r7100[0...99]

Par_circuit ring buffer fault/alarm code / Fault/alarm code

B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the fault/alarm code.
Dependency:
Refer to: r7101, r7102, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7101[0...99]

Par_circuit ring buffer data set number / Ring buffer Ds_no

B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
p7101 < 100:
Displays the Power unit Data Set number (PDS).
p7101 >= 100:
Displays the Voltage Sensing Module Data Set number (VSMDS)
Dependency:
Refer to: r7100, r7102, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
706
Calculated: -
Dyn. index: PDS, p0120
Units group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Units group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents