2 Parameters
2.2 List of parameters
Note:
For CBE20, certain SINAMICS parameters are newly evaluated and activated. An existing, cyclic bus connection is
interrupted.
r8843.0...2

BO: IF2 PZD state / IF2 PZD state

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: Communications
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the PROFIdrive PZD state.
Bit field:
Bit
00
01
02
Dependency:
Refer to: p2044
Note:
When using the "setpoint failure" signal, the bus can be monitored and an application-specific response triggered
when the setpoint fails.
p8844

IF2 fault delay / IF2 F delay

B_INF, ENC,
Can be changed: U, T
VECTOR_G
Data type: FloatingPoint32
P-Group: Communications
Not for motor type: -
Min
0 [s]
Description:
Sets the delay time to initiate fault F01910 after a setpoint failure.
The time until the fault is initiated can be used by the application. This means that is is possible to respond to the
failure while the drive is still operational (e.g. emergency retraction).
Dependency:
Refer to: r2043
p8848

IF2 PZD sampling time / IF2 PZD t_sample

CU_G130_DP,
Can be changed: C1(3)
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Communications
CU_G150_PN
Not for motor type: -
Min
1.00 [ms]
Description:
Sets the sampling time for the cyclic interface 2 (IF2).
Note:
The system only permits certain sampling times and after writing to this parameter, displays the value that has
actually been set.
For clock cycle synchronous operation, the specified bus cycle time applies (Tdp).
788
Signal name
Setpoint failure
Clock cycle synchronous operation active
Fieldbus oper
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
100 [s]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
16.00 [ms]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
0 [s]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4.00 [ms]