2.2 List of parameters
p0611[0...n]

I2t motor model thermal time constant / I2t mot_mod T

VECTOR_G
Can be changed: C2(1, 3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, REL, FEM
Min
0 [s]
Description:
Sets the winding time constant.
The time constant specifies the warm-up time of the cold stator winding when loaded with the motor standstill current
(rated motor current, if the motor standstill current is not parameterized) up until a temperature rise of 63 % of the
continuously permissible winding temperature has been reached.
Dependency:
This parameter is only used for synchronous motors (p0300 = 2xx, 4).
Refer to: r0034, p0612, p0615
Notice:
This parameter is automatically pre-set from the motor database for motors from the motor list (p0301).
When selecting a catalog motor, this parameter cannot be changed (write protection). Information in p0300 should be
carefully observed when removing write protection.
When exiting commissioning, p0612 is checked, and where relevant, is preassigned to a value that matches the
motor power, if a temperature sensor was not parameterized (see p0601).
Note:
When parameter p0611 is reset to 0, then this switches out the thermal I2t motor model (refer to p0612).
If no temperature sensor is parameterized, then the ambient temperature for the thermal motor model is referred to
p0625.
p0612[0...n]

Mot_temp_mod activation / Mot_temp_mod act

VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: -
Not for motor type: REL, FEM
Min
-
Description:
Setting to activate the motor temperature model.
Bit field:
Bit
00
01
02
09
Dependency:
For synchronous motors, when exiting commissioning, temperature model 1 is automatically activated if a time
constant has been entered in p0611.
Refer to: r0034, p0604, p0605, p0606, p0611, p0615, p0625, p0626, p0627, p0628
Note:
Mot_temp_mod: motor temperature model
Re bit 00:
This bit is used to activate/deactivate the motor temperature model for permanent-magnet synchronous motors.
Re bit 01:
This bit is used to activate/deactivate the motor temperature model for induction motors.
Re bit 02:
This bit is used to activate/deactivate the motor temperature model for 1FK7 motors without encoder.
Motor temperature model 3 cannot be simultaneously activated with another motor temperature model.
222
Signal name
Activating motor temperature model 1 (I2t)
Activate motor temperature model 2
Activate motor temperature model 3
Activate motor temperature model 2
expansions
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
20000 [s]
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 8017
Unit selection: -
Expert list: 1
Factory setting
0 [s]
Access level: 2
Func. diagram: 8017
Unit selection: -
Expert list: 1
Factory setting
0000 0010 0000 0010 bin