Permissible combinations in p0922 are:
p0922 = 391, 392, 393, 394
Re p0684 = 16:
Changing this evaluation procedure to p0684 = 0 or to p0684 = 1 is only activated after parameter save and POWER
ON.
Permissible combinations in p0922 are:
p0922 = 395
r0685

Central measuring probe control word display / Cen meas STW disp

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Commands
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the control word for the function "central measuring probe evaluation".
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
r0686[0...7]
CO: Central measuring probe measuring time rising edge / CenMeas t_meas 0/1
CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Displays, signals
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the measuring time for a rising edge at the digital input for the "central measuring probe evaluation" function.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0686[0]: Measuring time, rising edge measuring probe 1
r0686[1]: Measuring time, rising edge measuring probe 2
r0686[2]: Measuring time, rising edge measuring probe 3
r0686[3]: Measuring time, rising edge measuring probe 4
r0686[4]: Measuring time, rising edge measuring probe 5
r0686[5]: Measuring time, rising edge measuring probe 6
r0686[6]: Measuring time, rising edge measuring probe 7
r0686[7]: Measuring time, rising edge measuring probe 8
Note:
The parameter is only active for the evaluation procedure p0684 = 0, 1.
For p0684 = 16, r0686[0...7] = 0 is displayed.
234
Signal name
Falling edge measuring probe 1
Falling edge measuring probe 2
Falling edge measuring probe 3
Falling edge measuring probe 4
Falling edge measuring probe 5
Falling edge measuring probe 6
Falling edge measuring probe 7
Falling edge measuring probe 8
Rising edge measuring probe 1
Rising edge measuring probe 2
Rising edge measuring probe 3
Rising edge measuring probe 4
Rising edge measuring probe 5
Rising edge measuring probe 6
Rising edge measuring probe 7
Rising edge measuring probe 8
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-