p0010
Infeed commissioning parameter filter / INF comm par_filt
B_INF
Can be changed: C2(1), T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter filter to commission an infeed unit.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
Value:
0:
1:
2:
5:
29:
30:
Note:
The drive can only be powered up outside the drive commissioning (inverter enable). To realize this, this parameter
must be set to 0.
For p3900 not equal to 0, at the end of the quick commissioning, this parameter is automatically reset to 0.
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
Encoder DO commissioning parameter filter / EncDO com par_filt
ENC
Can be changed: C2(1), T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter filter to commission an encoder drive object.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
4:
5:
29:
30:
Note:
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
TB30 commissioning parameter filter / TB30 comm.par_filt
TB30
Can be changed: C2(1), T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter filter for commissioning a Terminal Board 30 (TB30).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
29:
30:
Dependency:
Refer to: p0970
Note:
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Ready
Quick commissioning
Power unit commissioning
Technological application/units
Only Siemens int
Parameter reset
Ready
Encoder commissioning
Technological application/units
Only Siemens int
Parameter reset
Ready
Only Siemens int
Parameter reset
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
30
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
41