Motor Temperature Sensor 3 Sensor Type Mds / Temp Sens3 Typ Mds; Motor Temperature Sensor 4 Sensor Type Mds / Temp Sens4 Typ Mds - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Value:
0:
10:
11:
12:
20:
30:
31:
32:
Dependency:
Refer to: r0458, p0600, p0601
Note:
This parameter is effective only when p0601 = 11.
PTC thermistor: Tripping resistance = 1650 Ohm
Information on using temperature sensors is provided in the following literature:
- hardware description of the appropriate components
- SINAMICS S120 Commissioning Manual
p4612[0...n]

Motor temperature sensor 3 sensor type MDS / Temp sens3 typ MDS

VECTOR_G
Can be changed: C2(3), U, T
Data type: Integer16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the sensor type of the third temperature sensor for the motor temperature monitoring.
Value:
0:
10:
11:
12:
20:
30:
31:
32:
Dependency:
Refer to: r0458, p0600, p0601
Note:
This parameter is effective only when p0601 = 11.
PTC thermistor: Tripping resistance = 1650 Ohm
Information on using temperature sensors is provided in the following literature:
- hardware description of the appropriate components
- SINAMICS S120 Commissioning Manual
p4613[0...n]

Motor temperature sensor 4 sensor type MDS / Temp sens4 typ MDS

VECTOR_G
Can be changed: C2(3), U, T
Data type: Integer16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the sensor type of the fourth temperature sensor for the motor temperature monitoring.
Value:
0:
10:
11:
12:
20:
30:
31:
32:
Dependency:
Refer to: r0458, p0600, p0601
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
No sensor
PTC fault
PTC alarm
PTC alarm & timer
KTY84, PT100, PT1000
Bimetallic NC contact fault
Bimetallic NC contact alarm
Bimetallic NC contact alarm & timer
No sensor
PTC fault
PTC alarm
PTC alarm & timer
KTY84, PT100, PT1000
Bimetallic NC contact fault
Bimetallic NC contact alarm
Bimetallic NC contact alarm & timer
No sensor
PTC fault
PTC alarm
PTC alarm & timer
KTY84, PT100, PT1000
Bimetallic NC contact fault
Bimetallic NC contact alarm
Bimetallic NC contact alarm & timer
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
32
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
32
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8016
Unit selection: -
Expert list: 1
Factory setting
10
Access level: 2
Func. diagram: 8016
Unit selection: -
Expert list: 1
Factory setting
10
639

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents