Operating Instructions 07/2007 Edition
SINAMICS G130/G150
Line harmonics filter
sinamics
s

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SINAMICS G150

  • Page 1 Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics...
  • Page 3 Safety information General Mechanical installation SINAMICS Electrical installation SINAMICS G130/G150 Line harmonics filters Maintenance and servicing Technical specifications Operating Instructions Control version V2.5 07/07 A5E01347987A...
  • Page 4 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 5: Table Of Contents

    Table of contents Safety information............................7 Warnings ............................7 Safety and operating instructions....................8 General..............................9 Mechanical installation..........................15 General ............................15 Dimension drawings........................16 Electrical installation ..........................19 Maintenance and servicing ........................25 Technical specifications........................... 27 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 6 Table of contents Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 7: Safety Information

    Safety information Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions.
  • Page 8: Safety And Operating Instructions

    The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. Line harmonics filters...
  • Page 9: General

    General Description Line harmonics filters are drive components designed for installation in electrical systems or machines. They must not be used in other electrical consumers since this could destroy the devices. WARNING Line harmonics filters must only be connected to symmetrical networks otherwise they can be destroyed.
  • Page 10 General Assignment of line harmonics filter and converter G130/G150 Table 2-1 Assignment of line harmonics filter, converter G130/G150 Line harmonics filter Associated converter G130 Associated converter cabinet Rated power of the G150 converter Supply voltage 380 – 480 V 3 AC 6SL3000-0JE36-1AA0 6SL3310-1GE35-0AA0 6SL3710-1GE35-0_A0...
  • Page 11 General Table 2-2 Assignment of converter G130, line contactor, and line reactor SINAMICS G130 Rated power Line contactor/circuit breaker Line reactor Supply voltage 380 – 480 V 3 AC 6SL3310-1GE35-0AA0 250 kW 3RT1476-6AP36 6SL3000-0CE35-1AA0 6SL3310-1GE36-1AA0 315 kW 3RT1476-6AP36 6SL3000-0CE36-3AA0 6SL3310-1GE37-5AA0 400 kW 3 x 3RT1466-6AP36 6SL3000-0CE37-7AA0...
  • Page 12 General Line harmonics filter Figure 2-1 Line harmonics filter in the delivery condition with degree of protection IP20 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 13 General Figure 2-2 Line harmonics filter with mounted canopy and degree of protection IP21 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 14 General Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 15: Mechanical Installation

    Mechanical installation General WARNING To ensure that the devices operate safely and reliably, they must be properly installed and commissioned by qualified personnel, taking into account the warnings provided in these operating instructions. In particular, the general and national installation and safety guidelines for high-voltage installations (e.g.
  • Page 16: Dimension Drawings

    Mechanical installation 3.2 Dimension drawings Dimension drawings Figure 3-1 Dimension drawing of line harmonics filter: 6SL3000-0JE36-1AA0, 6SL3000-0JH33- 3AA0 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 17 Mechanical installation 3.2 Dimension drawings Figure 3-2 Dimension drawing of line harmonics filter: 6SL3000-0JE38-4AA0, 6SL3000-0JH34-7AA0 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 18 Mechanical installation 3.2 Dimension drawings Figure 3-3 Dimension drawing of line harmonics filter: 6SL3000-0JE41-0AA0, 6SL3000-0JH35-8AA0, 6SL3000-0JH38- 1AA0 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 19: Electrical Installation

    Electrical installation Important safety precautions WARNING The line harmonics filters are operated with high voltages. All connection procedures must be carried out when the cabinet is de-energized. All work on the device must be carried out by trained personnel only. Death, serious injury, or substantial material damage can result if these warnings are not taken into account.
  • Page 20 Electrical installation Interface overview Figure 4-1 Connection overview of the line harmonics filter (600 mm wide) Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 21 Electrical installation Figure 4-2 Connection overview of the line harmonics filter (800 mm wide) Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 22 Electrical installation Figure 4-3 Connection overview of the line harmonics filter (1000 mm wide) Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 23 Electrical installation Connecting the line harmonics filter for SINAMICS G150 Figure 4-4 Connecting the line harmonics filter for SINAMICS G150 Line harmonics filters Operating Instructions, 07/07, A5E01347987A...
  • Page 24 Electrical installation Connecting the line harmonics filter for SINAMICS G130 Figure 4-5 Connecting the line harmonics filter for SINAMICS G130 Thermostatic switch connection A thermostatic switch is installed to protect the integrated reactors against overload. Its floating contacts must be integrated in the fault chain on the line side. Table 4-2 Thermostatic switch connection Terminal...
  • Page 25: Maintenance And Servicing

    Free Contact – providing you with free technical support ● In Europe / Africa Tel.: +49 (0)180 50 50 222 Fax: +49 (0)180 50 50 223 Internet: http://www.siemens.de/automation/support-request ● in America Tel.: +14232622522 Fax: +14232622289 E-mail: simatic.hotline@sea.siemens.com ●...
  • Page 27: Technical Specifications

    Technical specifications General technical specifications Table 6-1 General technical specifications Temperature class VDE: H UL: H Cooling method AN: Air cooling by means of natural convection Ambient conditions Operation Storage Transport Ambient temperature 0 °C to +40 °C -25°C to +55°C -25°C to +70 °C Humidity range (non- 5% to 95%...
  • Page 28 Technical specifications Table 6-3 Line harmonics filter, 500 V – 690 V, part 1 Category Unit Order number: 6SL3000- 0JH33-3AA0 0JH34-7AA0 0JH35-8AA0 Rated power Rated voltage 500 V to 690 V 3 AC ±10% at 50 Hz - can be rewired to: 500 V to 690 V 3 AC ±10% at 60 Hz Rated current Power loss...
  • Page 30 Siemens AG Automation and Drives A5E01347987A Large Drives PO Box 4743 90025 NUREMBERG GERMANY www.ad.siemens.com...