2 Parameters
2.2 List of parameters
Bit field:
Bit
00
01
02
Dependency:
Refer to: r9793
Note:
Re bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
Re bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
Re bit 02 = 1:
A safety-relevant component has been replaced. Data save required (p0977 = 1 or p0971 = 1 or "copy RAM to
ROM").
r9776
SI diagnostics / SI diag
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
The parameter is used for diagnostics.
Bit field:
Bit
00
01
02
03
Dependency:
Refer to: r9793
Note:
Re bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
Re bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
Re bit 02 = 1:
A safety-relevant component has been replaced. Data save required (p0977 = 1 or p0971 = 1 or "copy RAM to
ROM").
Re bit 03 = 1:
A safety-relevant component has been replaced. Acknowledge (p9702 = 29) and save (p0977 = 1 or p0971 = 1 or
"Copy RAM to ROM") required.
r9780
SI monitoring clock cycle (Control Unit) / SI monitor_clck CU
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [ms]
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on the Control Unit.
Dependency:
Refer to: r0110, p0115, r9880
Note:
Information regarding the relationship between monitoring clock cycle and response times can be found in the
following references:
- SINAMICS S120 Function Manual Safety Integrated
- technical documentation for the particular product
934
Signal name
Safety parameter changed POWER ON
required
Safety functions enabled
Safety component replaced and data save
required
Signal name
Safety parameter changed POWER ON
required
Safety functions enabled
Safety component replaced and data save
required
Safety component replaced and
acknowledge/save required
1 signal
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [ms]
List Manual (LH2), 04/2014, A5E03263479A
0 signal
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
- [ms]
SINAMICS G130/G150