2 Parameters
2.2 List of parameters
r0002

Encoder DO operating display / Enc DO op_display

ENC
Can be changed: -
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Operating display for encoder drive object.
Value:
0:
35:
45:
46:
60:
200:
250:
Notice:
For several missing enable signals, the corresponding value with the highest number is displayed.
r0002

DRIVE-CLiQ Hub Module operating display / Hub op_display

HUB
Can be changed: -
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Operating display for the DRIVE-CLiQ Hub Module.
Value:
0:
40:
50:
60:
70:
120:
200:
250:
Notice:
For several missing enable signals, the corresponding value with the highest number is displayed.
r0002

TB30 operating display / TB30 op_display

TB30
Can be changed: -
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Operating display for Terminal Board 30 (TB30).
Value:
0:
40:
60:
70:
80:
120:
200:
250:
Notice:
For several missing enable signals, the corresponding value with the highest number is displayed.
34
Encoder in cyclic operation
Carry out first commissioning (p0010)
Remove fault cause, acknowledge fault
Exit commissioning mode (p0009, p0010)
Encoder de-activated
Wait for booting/partial booting
Device signals a topology error
Module in cyclic operation
Module not in cyclic operation
Alarm
Fault
Initialization
Module de-activated
Wait for booting/partial booting
Device signals a topology error
Module in cyclic operation
Module not in cyclic operation
Fault
Initialization
Reset active
Module de-activated
Wait for run-up
Device signals a topology error
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
250
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
250
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
250
List Manual (LH2), 04/2014, A5E03263479A
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-