Co: If1 Profidrive Pzd Receive Word / If1 Pzd Recv Word - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r2050[0...9]

CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word

B_INF
Can be changed: -
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Connector output to interconnect PZD (setpoints) with word format received from the fieldbus controller.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
Note:
IF1: Interface 1
r2050[0...19]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Communications
CU_G150_PN
Not for motor type: -
Min
-
Description:
Connector output to interconnect PZD (setpoints) with word format received from the fieldbus controller.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
Note:
IF1: Interface 1
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: 4000H
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: 4000H
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
469

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents