Si Enable Safe Brake Control (Control Unit) / Si Enable Sbc Cu; Si Profisafe Address (Control Unit) / Si Profisafe Cu; Si Profisafe Telegram Selection (Control Unit) - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p9602

SI enable Safe Brake Control (Control Unit) / SI enable SBC CU

VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the enable signal for the function "Safe Brake Control" (SBC) on the Control Unit.
Value:
0:
1:
Dependency:
Refer to: p9802
Note:
The "Safe Brake Control" function is not activated until at least one safety monitoring function has been enabled (i.e.
p9501 not equal to 0 and/or p9601 not equal to 0).
It does not make sense to parameterize "no motor holding brake available" and enable "Safe Brake Control" (p1215
= 0, p9602 = p9802 = 1) if there is no motor holding brake.
The parameterization "motor holding brake the same as sequence control, connection via BICO" and "Safe Brake
Control" enabled (p1215 = 3, p9602 = 1, p9802 = 1) is not practical.
It is not permissible to parameterize "motor holding brake without feedback signals" and also enable "safe brake
control" (p1278 = 1, p9602 = 1, p9802 = 1).
CU: Control Unit
SBC: Safe Brake Control
SI: Safety Integrated
p9610

SI PROFIsafe address (Control Unit) / SI PROFIsafe CU

VECTOR_G
Can be changed: C2(95)
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Sets the PROFIsafe address for the Control Unit.
Dependency:
Refer to: p9810
p9611
SI PROFIsafe telegram selection (Control Unit) / SI Ps telegram CU
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the PROFIsafe telegram number for the Control Unit.
Value:
0:
30:
31:
900:
901:
902:
998:
Dependency:
Refer to: p9811, p60022
Note:
For p9601.3 = p9801.3 = 1 (PROFIsafe enabled), the following variants exist when parameterizing PROFIsafe
telegram 30:
- p9611 = p9811 = 998 and p60022 = 0
- p9611 = p9811 = 998 and p60022 = 30
- p9611 = p9811 = 30 and p60022 = 30
904
Inhibit SBC
Enable SBC
No PROFIsafe telegram selected
PROFIsafe standard telegram 30, PZD-1/1
PROFIsafe standard telegram 31, PZD-2/2
PROFIsafe SIEMENS telegram 900, PZD-2/2
PROFIsafe SIEMENS telegram 901, PZD-3/5
PROFIsafe SIEMENS telegram 902, PZD-3/6
Compatibility mode (as for firmware version < 4.5)
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
FFFE hex
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
998
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 2814
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
998