p1607[0...n]

Pulse technique stimulus / Puls stimulus

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, REL, FEM
Min
0.000 [mVs]
Description:
Sets the excitation amplitude (voltage-time pulse) for the pulse technique for estimating the continuous rotor position.
Dependency:
Refer to: p1605, p1750
r1608[0...6]

CO: Pulse technique response / Puls response

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: ASM, REL, FEM
Min
- [A]
Description:
Displays the signal responses to the excitation of the pulse technique.
Index:
[0] = Phase R
[1] = Phase S
[2] = D estimated
[3] = Q estimated
[4] = D estimated AC
[5] = Q estimated AC
[6] = Pointer length AC
Dependency:
Refer to: p1605, p1607, p1750
p1609[0...n]

I/f operation current setpoint / I/f op I_setp

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
0.00 [Arms]
Description:
Sets the stator current setpoint for operation of a separately-excited synchronous motor (FEM) in operating mode I/f
(p1300 = 18).
p1610[0...n]

Torque setpoint static (sensorless) / M_set static

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-200.0 [%]
Description:
Sets the static torque setpoint for sensorless vector control.
This parameter is entered as a percentage referred to the rated motor torque (r0333).
For sensorless vector control, when the motor model is shut down, an absolute current is impressed. p1610
represents the maximum load that occurs at a constant setpoint speed.
Notice:
p1610 should always be set to at least 10 % higher than the maximum steady-state load that can occur.
Note:
For p1610 = 0%, a current setpoint is calculated that corresponds to the no-load case (ASM: rated magnetizing
current).
For p1610 = 100 %, a current setpoint is calculated that corresponds to the rated motor torque.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
20000.000 [mVs]
Calculated: -
Dyn. index: -
Units group: 6_5
Scaling: p2002
Max
- [A]
Calculated: CALC_MOD_ALL
Dyn. index: DDS, p0180
Units group: 6_2
Scaling: -
Max
10000.00 [Arms]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
200.0 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
32.000 [mVs]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 2
Func. diagram: 6700, 6721,
6722, 6726
Unit selection: -
Expert list: 1
Factory setting
50.0 [%]