p0874
BI: Smart/ Basic Line Module operation / SLM/BLM operation
B_INF
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: -
Min
-
Description:
Setting to interconnect the ready signal for mixed operation of Smart Line Module (SLM) and Basic Line Module
(BLM).
In order that signal BO: r0873 is available at one of the infeeds, then BI: p0874 of the one infeed must be
interconnected to BO: r0863.0 of the other infeed.
Dependency:
Refer to: r0863, r0873
Note:
Mixed operation is not possible with the Active Line Module (ALM)!
p0894
Parking pre-setting / Parking pre-set
ENC, VECTOR_G
Can be changed: U, T
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Pre-setting for the "Parking axis" and "Parking encoder" function.
Bit field:
Bit
00
Dependency:
Refer to: p0480, p0897
Note:
Re bit 00:
If there is at least one BICO interconnection for "Parking axis" or "Parking encoder", this default setting is taken into
consideration during power-up.
p0895[0...n]
BI: Activate/de-activate power unit components / PU_comp act/deact
B_INF, VECTOR_G
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Sets the signal source to activate/de-activate a power unit component.
Dependency:
BI: p0895 = 0 signal
De-activate power unit components.
BI: p0895 = 1 signal
Activate power unit components
Refer to: p0125, r0126
Caution:
It is not permissible to de-activate drive objects with safety functions enabled.
Notice:
For Active Line Modules in the "Chassis" format, the Voltage Sensing Module (VSM, p0145) belonging to the power
unit is automatically activated/deactivated.
Note:
The power unit is only de-activated when the pulses are suppressed.
For units connected in parallel, when one of the power units is de-activated, then the enable in p7001 is withdrawn.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Default with interconnection
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Park
Calculated: -
Dyn. index: PDS, p0120
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8732, 8832
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
Do not park
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
FP
-
265