Co/Bo: Pe Energy-Saving Active/Inactive / Pe Save Act/Inact; Bi: Pe Set Switch-On Inhibit Signal Source / Pe Sw On_Inh S_Src; Motor Module Phase Shift Second System / Mm Ph_Sh 2Nd Sys - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r5613.0...1

CO/BO: Pe energy-saving active/inactive / Pe save act/inact

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: Communications
CU_G150_PN
Not for motor type: -
Min
-
Description:
Display and binector output for the state display PROFIenergy energy saving active or inactive.
Bit field:
Bit
00
01
Note:
Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
p5614

BI: Pe set switch-on inhibit signal source / Pe sw on_inh s_src

CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Unsigned32 / Binary
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibit".
Dependency:
Refer to: r5613
Note:
Pe: PROFIenergy profiles
p6397

Motor module phase shift second system / MM ph_sh 2nd sys

VECTOR_G
Can be changed: T
Data type: Integer16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the phase shift of the second system with respect to the first system for the motor module for a 12-pulse gating
unit.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
Dependency:
Refer to: p7003
Notice:
The parameter is only evaluated if p7003 = 2.
Note:
For p6397 = 0 the following applies: The second systems leads for a positive direction of rotation.
For p6397 = 1 the following applies: The second systems lags for a positive direction of rotation.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Pe active
Pe inactive
Shift by +30 °
Shift by -30 °
Shift by 0 °
Shift by +90 °
Shift by -90 °
Shift by +120 °
Shift by -120 °
Shift by +150 °
Shift by -150 °
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
8
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
695

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents