p1786[0...n]
Motor model Lh adaptation integral time / MotMod Lh Tn
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: PEM, REL, FEM
Min
10 [ms]
Description:
Sets the integral time for the Lh adaptation of the motor model for an induction motor (ASM).
r1787[0...n]
Motor model Lh adaptation corrective value / MotMod Lh corr
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: PEM, REL, FEM
Min
- [mH]
Description:
Displays the corrective value for the Lh adaptation of the motor model for an induction motor (ASM).
Dependency:
Refer to: p0826, p1780
Note:
The adaptation result is reset if the magnetizing inductance of the induction motor is changed (p0360, r0382). This
also happens when changing over the data set if a different motor is not being used (p0826).
The display of the inactive data sets is only updated when changing over the data set.
r1791
Motor model Lh adaptation power-on frequency / MotMod Lh f_on
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: PEM, REL, FEM
Min
- [Hz]
Description:
Displays the power-on stator frequency/ primary section frequency for the Lh adaptation for the induction motor
(ASM).
r1792
Motor model Lh adaptation power-on slip / MotMod Lh fslip
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: PEM, REL, FEM
Min
- [Hz]
Description:
Displays the power-on slip frequency for the Lh adaptation for the induction motor (ASM).
p1795[0...n]
Motor model kT adaptation integral time / MotMod kT Tn
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, REL, FEM
Min
10 [ms]
Description:
Sets the integral time of the kT adaptation of the motor model for a permanent-magnet synchronous motor (PEM).
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
- [mH]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [Hz]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [Hz]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
10000 [ms]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Hz]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Hz]
Access level: 3
Func. diagram: 6731
Unit selection: -
Expert list: 1
Factory setting
100 [ms]
427