r4022.0...3

CO/BO: TB30 digital inputs status / TB30 DI status

TB30
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the status of the digital inputs of the Terminal Board 30 (TB30).
Bit field:
Bit
00
01
02
03
Dependency:
Refer to: r4023
Note:
DI: Digital Input
r4022.0...11

CO/BO: TM31 digital inputs status / TM31 DI status

TM31
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the status of the digital inputs of Terminal Module 31 (TM31).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
Dependency:
Refer to: r4023
Note:
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
r4023.0...3

BO: TB30 digital inputs status inverted / TB30 DI status inv

TB30
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the inverted status of the digital inputs of the Terminal Board 30 (TB30).
Bit field:
Bit
00
01
02
03
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
DI 0 (X481.1)
DI 1 (X481.2)
DI 2 (X481.3)
DI 3 (X481.4)
Signal name
DI 0 (X520.1)
DI 1 (X520.2)
DI 2 (X520.3)
DI 3 (X520.4)
DI 4 (X530.1)
DI 5 (X530.2)
DI 6 (X530.3)
DI 7 (X530.4)
DI/DO 8 (X541.2)
DI/DO 9 (X541.3)
DI/DO 10 (X541.4)
DI/DO 11 (X541.5)
Signal name
DI 0 (X481.1)
DI 1 (X481.2)
DI 2 (X481.3)
DI 3 (X481.4)
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
High
High
High
High
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
High
High
High
High
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 9099, 9100
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Access level: 1
Func. diagram: 9549, 9550,
9552, 9560, 9562
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Access level: 1
Func. diagram: 9099, 9100
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
FP
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
601

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents