Statistic Number Of Entries / Statistic Size; Statistic Components Id / Statistic Compid; Statistic Drive-Cliq Acyclic Communication / Statistic - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9220

Statistic number of entries / Statistic size

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Supplies the number of entries in p9222.
Dependency:
In p9221, the component Id is set whose statistic entries are to be displayed.
Refer to: p9221
p9221

Statistic components Id / Statistic compId

CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0000 hex
Description:
Selects the component Id whose statistics are to be displayed in p9222.
r9222[0...n]

Statistic Drive-CLiQ acyclic communication / Statistic

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Represents the statistic of acyclic Drive-CLiQ communication.
The component is preset in p9221.
The entry comprises the following elements:
Index 0: Parameter Id
Index 1: Number of messages sent.
Index 2: Minimum time of all acyclic requests referred to the parameter Id (index 0).
Index 3: Maximum time of all acyclic requests referred to the parameter Id (index 0).
Index 4: Average of all acyclic requests referred to the parameter Id (index 0).
The time unit is 10us.
Dependency:
The number of statistic entries is displayed in p9220.
In p9221, the component Id can be set whose statistic is to be displayed.
Refer to: r9220, p9221
Note:
As a statistic entry comprises 5 data, when calling the entries via the terminal, a size that represents a multiple of 5
must be specified.
Example: the 2nd entry must be called:
rdp 1 9222 5 5
or
rdpa 1 9222 5 5.
836
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
00FF hex
Calculated: -
Dyn. index: r9220
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0002 hex
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents