Emc Test Results (Emission, Immunity) - Danfoss FC 300 Design Manual

Vlt automationdrive
Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

FC 300 Design Guide

EMC Test Results (Emission, Immunity)

The following test results have been obtained using a system with an adjustable frequency drive (with options if
relevant), a shielded control cable, a control box with potentiometer, as well as a motor and motor cable.
FC 301/FC 302
200-240 V
380-500 V
600 V no filter
Setup
FC 301/FC 302 H2
0-3.7 kW 200-240 V
0-7.5 kW 380-500 V
FC 301 with integrated
filter H1
0-3.7 kW 200-240 V
0-7.5 kW 380-480 V
FC 302 with integrated
filter H1
0-3.7 kW 200-240 V
0-7.5 kW 380-500 V
FC 301 11-22 kW
380-500 V
FC 302 11-22 kW
380-500 V
FC 301 with integrated
filter H1
11-22 kW 380-500 V
FC 302 with integrated
filter H2
11-22 kW 380-500 V
Hx is without filter
42
Introduction to FC 300
Conducted emission
Industrial environment
EN 55011
EN 55011
Class A1
Class A2
16 ft (5 m)
No
16 ft (5 m)
No
164 ft (50
m)
246 (75 m)
164 ft (50
246 (75 m)
m)
490 ft (150
m)
490 ft (150 m)
490 ft (150
490 ft (150 m)
m)
82 ft (25 m)
No
82 ft (25 m)
No
164 ft (50
246 (75 m)
m)
490 ft (150
490 ft (150 m)
m)
MG.33.B6.22 - VLT is a registered Danfoss trademark
Radiated emission
Housing,
Industrial
trades
environment
and light
industries
EN 55011
EN 55011
Class B
Class A1
No
No
No
No
33 ft (10 m)
Yes
33 ft (10 m)
Yes
130 ft (40 m)
Yes
130 ft (40 m)
Yes
No
No
No
No
33 ft (10 m)
Yes
130 ft (40 m)
Yes
Housing, trades
and light
industries
EN 55011 Class B
No
No
No
No
No
No
No
No
No
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents