Mains Supply 3 x 200 - 240 VAC
FC 301/FC 302
Shaft Output [kW]
Output current
Continuous
(3 x 200-240 V ) [A]
Intermittent
(3 x 200-240 V ) [A]
Continuous
KVA (208 V AC) [KVA]
Max. cable size
(mains, motor, brake)
2)
[AWG]
[mm
Max. input current
Continuous
(3 x 200-240 V ) [A]
Intermittent
(3 x 200-240 V ) [A]
Max. pre-fuses
Environment
Estimated power loss
at rated max. load [W]
Enclosure IP 20/IP 21
Enclosure IP 20 (FC 301 only)
Enclosure IP 55
Weight, enclosure IP20 [kg]
A1 (IP 20)
4)
Efficiency
0.25 - 3.7 kW only available as 160% high overload.
FC 300 Selection
PK25
0.25
1.8
2.9
0.65
2
]
1.6
2.6
1)
[A]
10
21
4)
A2
A1
A5
4.7
2.7
0.94
MG.33.B7.02 - VLT is a registered Danfoss trademark
PK37
PK55
PK75
P1K1
0.37
0.55
0.75
1.1
2.4
3.5
4.6
6.6
3.8
5.6
7.4
10.6
0.86
1.26
1.66
2.38
24 - 10 AWG
0.2 - 4 mm
2.2
3.2
4.1
5.9
3.5
5.1
6.6
9.4
10
10
10
20
29
42
54
63
A2
A2
A2
A2
A1
A1
A1
A1
A5
A5
A5
A5
4.7
4.8
4.8
4.9
2.7
2.7
2.7
2.7
0.94
0.95
0.95
0.96
P1K5
P2K2 P3K0 P3K7
1.5
2.2
3
3.7
7.5
10.6
12.5
16.7
12.0
17.0
20.0
26.7
2.70
3.82
4.50
6.00
2
6.8
9.5
11.3
15.0
10.9
15.2
18.1
24.0
20
20
32
32
82
116
155
185
A2
A2
A3
A3
-
-
-
-
A5
A5
A5
A5
4.9
4.9
6.6
6.6
2.7
-
-
-
0.96
0.96
0.96
0.96
49