Quick Setup

"
0-01 Language
Option:
*
English (ENGLISH)
German (DEUTSCH)
French (FRANCAIS)
Danish (DANSK)
Spanish (ESPANOL)
Italian (ITALIANO)
Chinese (CHINESE)
Finnish (FINNISH)
English US (ENGLISH US)
Greek (GREEK)
Portuguese (PORTUGUESE)
Slovenian (SLOVENIAN)
Korean (KOREAN)
Japanese (JAPANESE)
Turkish (TURKISH)
Traditional Chinese
Bulgarian
Serbian
Romanian (ROMANIAN)
Hungarian (HUNGARIAN)
Czech
Polish (POLISH)
Russian
Thai
Bahasa Indonesian (BAHASA
INDONESIAN)
Function:
Defines the language to be used in display.
The frequency converter can be delivered with
4 various language packages. English and
German are included in all packages. English
cannot be erased or manipulated.
Language package 1 consists of:
English, German, French, Danish, Spanish,
Italian and Finnish.
Language package 2 consists of:
English, German, Chinese, Korean, Japanese,
Thai and Bahasa Indonesian.
Language package 3 consists of:
English, German, Slovenian, Bulgarian, Serbian,
Romanian, Hungarian, Czech and Russian.
Language package 4 consists of:
English, German, Spanish, English US, Greek,
Brazilian Portuguese, Turkish and Polish.
*
default setting
( )
display text
36
How to Programme
[0]
Enter the nominal motor power in kW according
[1]
to the motor nameplate data. The default value
[2]
corresponds to the nominal rated output of the unit.
[3]
This parameter cannot be adjusted while
[4]
the motor is running.
[5]
[10]
[20]
[22]
[27]
[28]
[36]
Enter the nominal motor voltage according to
[39]
the motor nameplate data. The default value
[40]
corresponds to the nominal rated output of
[41]
the unit. This parameter cannot be adjusted
[42]
while the motor is running.
[43]
[44]
[45]
[46]
*
[47]
[48]
[49]
[50]
Select the motor frequency value from the motor
[51]
nameplate data. Alternatively, set the value for
motor frequency to be infinitely variable. If a value
different from 50 Hz or 60 Hz is selected, it is
necessary to adapt the load independent settings
in par. 1-50 to 1-53. For 87 Hz operation with
230/400 V motors, set the nameplate data for
230 V/50 Hz. Adapt par. 4-13 Motor Speed High
Limit [RPM) and par. 3-03 Maximum Reference
to the 87 Hz application. This parameter cannot
be adjusted while the motor is running.
Enter the nominal motor current value from
the motor nameplate data. The data are
used for calculating torque, motor protection
etc. This parameter cannot be adjusted
while the motor is running.
[ ]
value for use in communication via serial communication port
MG.33.A7.02 - VLT is a registered Danfoss trademark
1-20 Motor Power [kW]
Range:
Size dependent
Function:
1-22 Motor Voltage
Range:
200-600 V
Function:
1-23 Motor Frequency
Option:
50 Hz (50 HZ)
60 Hz (60 HZ)
Min - Max motor frequency: 20 - 300 Hz
Function:
1-24 Motor Current
Range:
Motor type dependent.
Function:
[M-TYPE]
[M-TYPE]
[50]
[60]

Advertisement