FC 300 Operating Instructions

Pulse Start/Stop

"
Terminal 18 = Par. 5-10 [9] Latched start
Terminal 27= Par. 5-12 [6] Stop inverse
Terminal 37 = Safe stop (FC 302 and FC 301 A1 only!)

Speed Up/Down

"
Terminals 29/32 = Speed up/down.
Terminal 18 = Par. 5-10 [9] Start(default)
Terminal 27 = Par. 5-12 [19] Freeze reference
Terminal 29 = Par. 5-13 [21] Speed up
Terminal 32 = Par. 5-14 [22] Speed down
Note: Terminal 29 only in FC 302.

Potentiometer Reference

"
Voltage reference via a potentiometer.
Reference Resource 1 = [1] Analogue
input 53 (default)
Terminal 53, Low Voltage = 0 Volt
Terminal 53, High Voltage = 10 Volt
Terminal 53, Low Ref./Feedback = 0 RPM
Terminal 53, High Ref./Feedback = 1500 RPM
Switch S201 = OFF (U)
26