Fc 300 Selection; Mg.33.B9.22 - Vlt ® Is A Registered Danfoss Trademark; Electrical Data - Danfoss FC 300 Design Manual

Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

FC 300 Design Guide

4. FC 300 Selection

4.1. Electrical Data

Line Supply 3 x 200-240 VAC
FC 301/FC 302
Output current
Max. input current
0.33-4 hp [0.25-3.7 kW] only available as 160% high overload.
PK25
Typical Shaft Output
0.25
[kW]
Enclosure IP 20/IP 21
A2
Enclosure IP 20 (FC 301
A1
only)
Enclosure IP 55, 66
A5
Continuous
1.8
(3 x 200-240 V) [A]
Intermittent
2.9
(3 x 200-240 V) [A]
Continuous
0.65
KVA (208 V AC) [KVA]
Max. cable size (line
power, motor, brake)
[mm
2
(AWG
2)
)]
Continuous
1.6
(3 x 200-240 V) [A]
Intermittent
2.6
(3 x 200-240 V) [A]
1)
Max. pre-fuses
[A]
10
Environment
Estimated power loss
at rated max. load [W]
21
4)
Weight, enclosure IP
4.7
20 [kg]
A1 (IP20)
2.7
A5 (IP 55, 66)
13.5
Efficiency
4)
0.94
MG.33.B9.22 - VLT
®
is a registered Danfoss trademark.
PK37
PK55
PK75
P1K1
P1K5 P2K2 P3K0 P3K7
0.37
0.55
0.75
1.1
A2
A2
A2
A2
A1
A1
A1
A1
A5
A5
A5
A5
2.4
3.5
4.6
6.6
3.8
5.6
7.4
10.6
12.0
0.86
1.26
1.66
2.38
2.70
0.2 - 4 (24 - 10)
2.2
3.2
4.1
5.9
3.5
5.1
6.6
9.4
10.9
10
10
10
20
29
42
54
63
4.7
4.8
4.8
4.9
2.7
2.7
2.7
2.7
13.5
13.5
13.5
13.5
13.5
0.94
0.95
0.95
0.96
0.96
4. FC 300 Selection
1.5
2.2
3
3.7
A2
A2
A3
A3
A1
-
-
-
A5
A5
A5
A5
7.5
10.6
12.5
16.7
17.0
20.0
26.7
3.82
4.50
6.00
6.8
9.5
11.3
15.0
15.2
18.1
24.0
20
20
32
32
82
116
155
185
4.9
4.9
6.6
6.6
2.7
-
-
-
13.5
13.5
13.5
0.96
0.96
0.96
4