Rate-Interval - Dell Force10 S4810P Reference Manual

Ftos command line reference guide for the s4810 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 S4810P:
Table of Contents

Advertisement

FTOS(conf-if-vl-10)#untagged gi 7/0
FTOS(conf-if-vl-10)#interface vlan 20
FTOS(conf-if-vl-20)#tagged gi 7/0
FTOS(conf-if-vl-20)#
Example
FTOS(conf-if-vl-20)#do show interfaces switchport
Name: GigabitEthernet 7/0
802.1QTagged: Hybrid
Vlan membership:
Vlan
Native
FTOS(conf-if-vl-20)#
Example (Vlan)
FTOS(conf-if-vl-20)#interface vlan 10
FTOS(conf-if-vl-10)#no untagged gi 7/0
FTOS(conf-if-vl-10)#interface vlan 20
FTOS(conf-if-vl-20)#no tagged gi 7/0
FTOS(conf-if-vl-20)#interface gi 7/0
FTOS(conf-if-gi-7/0)#no portmode hybrid
FTOS(conf-if-vl-20)#
Related
show interfaces switchport
Commands
the switch.
switchport
vlan-stack trunk

rate-interval

Configure the traffic sampling interval on the selected interface.
C-Series, E-Series, S-Series, Z-Series
Syntax
rate-interval seconds
Parameters
seconds
Defaults
299 seconds
Command Modes
INTERFACE
Command History
Version 8.3.11.1
Version 8.1.1.0
Version 7.6.1.0
Version 7.5.1.0
786
10,
Vlan 20
VlanId: 10
– displays the configuration of switchport (Layer 2) interfaces on
– places the interface in a Layer 2 mode.
– specifies an interface as a trunk port to the Stackable VLAN network.
Enter the number of seconds for which to collect traffic data. The
range is 30 to 299 seconds.
NOTE: Because polling occurs every 15 seconds, the number of
seconds designated here will round to the multiple of 15 seconds
lower than the entered value. For example, if 44 seconds is
designated, it will round to 30; 45 to 59 seconds will round to 45,
and so forth.
Introduced on the Z9000.
Introduced on the E-Series ExaScale.
Introduced on the S-Series.
Introduced on the C-Series.