period
Default
Command Modes
CONFIGURATION
Command History
Version 8.3.12.0
Version 8.1.1.0
Version 7.5.1.0
Version 7.6.1.0
Usage
If you disable auto failover, enter the redundancy auto-failover-limit (without any
Information
parameters) to set auto failover to the default parameters (Count 3, Period 60 minutes). Use the
show redundancy command to view the redundancy status.
When you change one or both of the optional parameters, FTOS checks that the interval
between auto failovers is more than five (5) minutes. If the interval is less, FTOS returns a
configuration error message.

redundancy disable-auto-reboot

Prevent the system from auto-rebooting the failed module.
C-Series, E-Series, S4810
Syntax
redundancy disable-auto-reboot [rpm| card number | all]
To return to the default, use the no redundancy disable-auto-reboot rpm
command.
Parameters
rpm
Default
Disabled (that is, the failed module is automatically rebooted).
Command Modes
CONFIGURATION
Command History
Version 8.3.12.0
Version 8.3.1.0
Version 8.1.1.0
Version 7.6.1.0
minutes
Enter a duration in which to allow a number of automatic failovers
(limited to the number defined in the count parameter). The range is 5
to 9000 minutes. The default is 60 minutes.
Count: 3
Period: 60 minutes
Introduced on the S4810.
Introduced on the E-Series ExaScale.
Introduced on the C-Series.
Introduced on the E-Series
Enter the keyword rpm to disable auto-reboot of the failed RPM.
Introduced on the S4810.
Added the all option.
Introduced on the E-Series ExaScale.
Introduced on the E-Series