auto-cost
Specify how the OSPF interface cost is calculated based on the reference bandwidth method.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
auto-cost [reference-bandwidth ref-bw]
To return to the default bandwidth or to assign cost based on the interface type, use the no
auto-cost [reference-bandwidth] command.
Parameters
ref-bw
Defaults
100 megabits per second.
Command Modes
ROUTER OSPF
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.8.1.0
Version 7.6.1.0
Version 7.5.1.0
pre-Version
6.1.1.1
clear ip ospf
Clear all OSPF routing tables.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
clear ip ospf process-id [process]
Parameters
process-id
process
Command Modes
EXEC Privilege
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.8.1.0
Version 7.6.1.0
Version 7.5.1.0
1148
(OPTIONAL) Specify a reference bandwidth in megabits per second.
The range is 1 to 4294967. The default is 100 megabits per second.
Introduced on the Z9000.
Introduced on the S4810.
Added support for the Multi-Process OSPF.
Introduced on the S-Series.
Introduced on the C-Series.
Introduced on the E-Series.
Enter the OSPF Process ID to clear a specific process. If no Process
ID is entered, all OSPF processes are cleared.
(OPTIONAL) Enter the keyword process to reset the OSPF process.
Introduced on the Z9000.
Introduced on the S4810.
Added support for the Multi-Process OSPF.
Introduced on the S-Series.
Introduced on the C-Series.