Extreme Networks ExtremeWare XOS Command Reference Manual page 1225

Software version 11.5
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
If your STPD has the same name as another component, for example a VLAN, Extreme Networks
recommends that you specify the identifying keyword as well as the name. If you do not specify the
keyword, an error message similar to the following is displayed:
stpd
%% Ambiguous command:
In this example, to view all of the port settings of STPD Test, enter
If your STPD has a name unique only to that STPD, the keyword
Example
The following command displays the state of slot 3, ports 1 through 3 on an STPD named s0:
show stpd S0 ports 3:1-3:3
The following is sample output from this command:
Port Mode
State
3:1
802.1D FORWARDING 100
3:2
802.1D FORWARDING 100
3:3
802.1D FORWARDING 100
Total Ports: 3
------------------------- Flags: ----------------------------
1:
e=Enable, d=Disable
2: (Port role)
R=Root, D=Designated, A=Alternate, B=Backup, M=Master
3: (Config type)
b=broadcast, p=point-to-point, e=edge, a=auto
4: (Oper. type)
b=broadcast, p=point-to-point, e=edge
5:
p=proposing, a=agree
6: (partner mode) d = 802.1d, w = 802.1w, m = mstp
7:
i = edgeport inconsistency
8:
S = edgeport safe guard active
s = edgeport safe guard configured but inactive
9:
B = Boundary, I = Internal
The following command displays the detailed information for the ports in STPD S0:
show stpd S0 ports detail
The following is sample output from this command:
Stpd: s0
Port: 1:1
External Path Cost:
Port Mode: 802.1D
Port State:
FORWARDING
Port Priority: 16
Designated Root:
00:00:00:00:00:00:00:00
Designated Bridge: 00:00:00:00:00:00:00:00
Partner STP version: Dot1d
Edge Port Safe Guard: Disabled
Participating Vlans: Default
Stpd: s0
Port: 1:2
External Path Cost:
Port Mode: 802.1D
ExtremeWare XOS 11.5 Command Reference Guide
"show Test ports"
Cost
Flags
Priority Port ID Designated Bridge
e------- 16
e------- 16
e------- 16
PortId: 8002
Topology Change Ack: FALSE
PortId: 8002
show stpd Test ports
is optional.
stpd
16641
00:00:00:00:00:00:00:00
16642
00:00:00:00:00:00:00:00
16643
00:00:00:00:00:00:00:00
Stp: ENABLED
Path Cost: 19
Designated Cost: 0
Designated Port Id: 0
Stp: ENABLED
Path Cost: 19
show stpd ports
.
1225

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.5

Table of Contents