ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.

configure netlogin ports mode

configure netlogin ports [all | <port_list>] mode [mac-based-vlans | port-
based-vlans]
Description
Configures the netlogin port's mode of operation.
Syntax Description
all
port_list
mac-based-vlans
port-based-vlans
Default
The default setting is
port-based-vlans
Usage Guidelines
Use this command to configure netlogin MAC-based VLANs on a netlogin port.
If you modify the mode of operation to
that port, the mode of operation automatically returns to
When you change the netlogin port's mode of operation, the switch deletes all currently known
supplicants from the port and restores all VLANs associated with that port to their original state. In
addition, by selecting
mac-based-vlans
from this port. Netlogin now controls these VLANs.
With netlogin MAC-based operation, every authenticated client has an additional FDB flag that
indicates a translation MAC address. If the supplicant's requested VLAN does not exist on the port, the
switch adds the requested VLAN.
Important Rules and Restrictions. This section summarizes the rules and restrictions for configuring
netlogin MAC-based VLANs:
If you attempt to configure the port's mode of operation before enabling netlogin, the switch
displays an error message similar to the following:
ERROR: The following ports do not have NetLogin enabled; 1
To enable netlogin on the switch, use the following command to enable netlogin and to specify an
authentication method (for example, 802.1x—identified as dot1.x in the CLI):
enable netlogin
dot1x
To enable netlogin on the ports, use the following command to enable netlogin and to specify an
authentication method (for example, 802.1x—identified as dot1.x in the CLI):
enable netlogin ports
ExtremeWare XOS 11.5 Command Reference Guide
Specifies all netlogin ports.
Specifies one or more netlogin ports.
Allows more than one untagged VLAN.
Allows only one untagged VLAN. This is the default behavior.
.
mac-based-vlans
, you are unable to manually add or delete untagged VLANs
1:1 dot1x
configure netlogin ports mode
and later disable all netlogin protocols on
.
port-based-vlans
1065

Advertisement