ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
Software redundant port:
auto-polarity:
The added output displays information about the mode of operation for the netlogin port.
—The term MAC-based appears next to the tag number.
●
VLAN cfg
●
Netlogin port mode
appears and the network login port mode of operation.
To view information about the ports that are temporarily added in MAC-based mode for netlogin, due
to discovered MAC addresses, use the following command:
show vlan detail
The following is sample output from this command:
VLAN Interface with name Default created by user
Tagging:
Priority:
Virtual router: VR-Default
STPD:
Protocol:
Loopback:
NetLogin:
Rate Shape:
QosProfile:
Ports:
26.
Untag:
Flags: (*) Active, (!) Disabled, (g) Load Sharing port
(b) Port blocked on the vlan, (a) Authenticated NetLogin Port
(u) Unauthenticated NetLogin port, (m) Mac-Based port
The flags associated with netlogin include:
—Indicates an authenticated network login port.
●
a
—Indicates an unauthenticated network login port.
●
u
—Indicates that the netlogin port operates in MAC-based mode.
●
m
Example
The following example configures the netlogin ports mode of operation:
configure netlogin ports 1:1-1:10 mode mac-based-vlans
History
This command was first available in ExtremeWare XOS 11.3.
ExtremeWare XOS 11.5 Command Reference Guide
Disabled
Enabled
—This output was added to display the port mode of operation. Mac based
802.1Q Tag 1
802.1P Priority 0
s0(Disabled,Auto-bind)
Match all unfiltered protocols
Disable
Disabled
Disabled
None configured
(Number of active ports=2)
*1m,
*2,
3,
8,
9,
10,
15,
16,
17,
22,
23,
24,
configure netlogin ports mode
4,
5,
6,
11,
12,
13,
18,
19,
20,
25,
26
7,
14,
21,
1067