Fuser Temperature Cycling - Oki B6100 Technical Manual

Base engine
Hide thumbs Also See for B6100:
Table of Contents

Advertisement

Principles of Operation

Fuser Temperature Cycling

Fuser temperature does not remain at a single, constant temperature. Fuser temperature follows a sine
wave through a range of temperatures. FUSER TEMPERATURE CHECK (software diagnosis) displays
the contents of NVRAM (FUSER TEMP.SET).
Temperature name
High Trouble Temperature
Fuser Off Temperature
Fuser control temperature
Fuser On Temperature
Low Trouble Temperature
13-74
o
Approximately 215
C (Standby temperature + approximately 35
Fuser control temperature +/- 0
Standby temperature (180
Running temperature (180
Fuser control temperature - 2
o
Approximately 155
C (Standby temperature - approximately 25
OKI B6100 Laser Printer - Base Engine Technical Manual
Temperature value
o
C
o
C)
o
C)
o
C
o
C)
o
C)
Version 1.0