Removal
1. Remove the Cover Assy Front (RRP 1.1.8).
2. Remove the Cover Front L/H (RRP 1.1.10).
3. Remove the Chute MBF Assy (RRP 4.1.1).
4. Remove the Spring MBF (RRP 4.1.9).
5. Remove the Gear Pick Up (RRP 4.1.10).
6. Remove the one screw securing the Solenoid Pick Up to the Chute MBF Assy .
7. Remove the Solenoid Pick Up from the Chute MBF Assy .
Replacement
1. Align the Solenoid Pick Up with its mount position to the Chute MBF Assy .
2. Secure the Solenoid Pick Up to the Chute MBF Assy with one screw.
3. Mount the Gear Pick Up (RRP 4.1.10).
4. Mount the Spring MBF (RRP 4.1.9).
5. Mount the Chute MBF Assy (RRP 4.1.1).
6. Mount the Cover Front L/H (RRP 1.1.10).
7. Mount the Cover Assy Front (RRP 1.1.8).
OKI B6100 Laser Printer - Base Engine Technical Manual
Version 1.0
RRP 4.1.8 Solenoid Pick Up (PL4.1.23) continued
Removal and Replacement Procedures (RRPs)
10-93