ROS Control
Warm-up
The ROS completes warm-up when the SOS signal intervals are shorter than the READY reference value,
during three consecutive samplings of the SOS signal interval, and when the actual LD laser power
reaches the value that was set in Configuration Code 2. The READY interval for the SOS signal is approx-
imately 98% of the SOS interval when the ROS Motor is rotating at the rated speed of 277.41 μs for 600
dpi and 138.71μs for 1200 dpi.
ROS Motor and LD Control in Various Printer Modes
Printer Mode
On-line Mode
Printing Test Mode
Diagnostic Mode
Configuration Mode
Printable Area
OKI B6100 Laser Printer - Base Engine Technical Manual
Version 1.0
ROS Motor and LD Control
The ROS Motor and the LD are both controlled by the
Printer Controller.
The ROS Motor is stopped. The LD is switched on only
when SOS is detected
The ROS Motor and the LD are always on.
The ROS Motor is always on. The LD is switched on
only when SOS is detected.
Principles of Operation
13-71