Oki B6100 Technical Manual page 303

Base engine
Hide thumbs Also See for B6100:
Table of Contents

Advertisement

Removal
1. Remove the Cover Assy Front (RRP 1.1.8).
2. Remove the Cover Front L/H (RRP 1.1.10).
3. Remove the Cover Assy Rear (RRP 1.2.3).
4. Remove the Cover Assy Top (RRP 1.1.4).
5. Remove the Eliminator Assy Exit (RRP 7.1.1).
6. Remove the Actuator Full Stack (RRP 7.1.2).
7. Unplug the connector (P/J311) on the Sensor Photo:Exit .
8. Disengage five hooks of Sensor Photo:Exit secured to the Chute Assy Exit in the printer.
9. Remove the Sensor Photo:Exit from the Chute Assy Exit .
Replacement
1. Aligning the position exactly, mount the Sensor Photo:Exit on the Chute Assy Exit in the
printer.
2. Secure the Sensor Photo:Exit to the Chute Assy Exit with five hooks.
3. Plug the connector (P/J311) to the Sensor Photo:Exit .
4. Mount the Actuator Full Stack (RRp 7.1.2)
5. Mount the Eliminator Assy Exit (RRP 7.1.1).
6. Mount the Cover Assy Top (RRP 1.1.4).
7. Mount the Cover Assy Rear (RRP 1.2.3).
8. Mount the Cover Front L/H (RRP 1.1.10).
9. Mount the Cover Assy Front (RRP 1.1.8).
OKI B6100 Laser Printer - Base Engine Technical Manual
Version 1.0
RRP 7.1.5 Sensor Photo:Exit (PL7.1.16) continued
Removal and Replacement Procedures (RRPs)
10-149

Advertisement

Table of Contents
loading

Table of Contents