Input Tests - Oki B6100 Technical Manual

Base engine
Hide thumbs Also See for B6100:
Table of Contents

Advertisement

1.5.6 Input Tests

The input tests allow you to test the sensors and switches located in the printer, display fuser
temperature activity in a Hex code, and display the ROM checksum.
To enter the Input Tests menu see Entering Diagnostics (1.5.2) and Navigating Through Diagnostics
(1.5.3).
The Sensor Test displays three zeros and a two digit Hex code. Each time a sensor is actuated or
de-actuated, the two digit Hex code changes.
The Fuser Temp Set and Fuser Temp Read are for checking fuser temperature activity only. You
cannot set the fuser temperature.
ROM Checksum displays the ROM Checksum.
Test
Sensor Test
Fuser Temp Set
Fuser Temp Read
ROM Checksum
OKI B6100 Laser Printer - Base Engine Technical Manual
Version 1.0
Table 2. Input Tests
Component Tested
All sensors and switches
Current fuser factory setting
Current fuser temperature
ROM Checksum
Notes
The two digit Hex code changes with
each actuation and de-actuation of a
sensor or switch.
Displays a two digit Hex code that indi-
cates the fuser temperature set by the
factory. This number can be used
when escalating a fuser problem. The
fuser temperature is not field adjust-
able.
Displays a two digit Hex code that indi-
cates the fuser temperature. As the
fuser operates at all times in a certain
temperature range (heating and cool-
ing), a temperature variation, indicated
by a constantly changing Hex code, is
not a sign of trouble.
Displays the ROM checksum.
Diagnostic Mode