RRP 2.2.5 Connector(PL2.2.25) and Guide Socket(PL2.2.27) continued
Removal
1. Draw the Cassette Assy (PL2.1.1) from the printer.
In the following steps, take care not to drop and miss the Spring Motor
(PL2.2.19).
2. Remove the two screws securing the Holder L (PL2.2.21) to the Cassette Assy .
3. Remove the Spring Motor (PL2.2.19) with Holder L from the Cassette Assy .
In the following steps, take care not to drop and miss the Spring (PL2.2.26).
4. Unplug the connector (P/J673) of the Motor Assy (PL2.2.22)from the Connector .
5. Remove the two screws securing the Guide Socket to the Cassette Assy .
6. Remove the Guide Socket together with Connector from the Cassette Assy .
7. Remove the Spring (RRP 2.2.26).
8. Sliding the Connector upward, disconnect it from the Guide Socket .
Replacement
1. Aligning the Connector with the rail of Guide Socket , slide the Connector downward to
connect.
In the following steps, take care not to drop and miss the Spring (PL2.2.26).
2. Mount the Spring (RRP 2.2.26).
3. Aligning the position exactly, mount the Guide Socket together with Connector on the
Cassette Assy .
4. Secure the Guide Socket to the Cassette Assy with two screws.
In the following steps, take care not to drop and miss the Spring Motor
(PL2.2.19).
5. Plug the connector (P/J673) of the Motor Assy (PL2.2.22)to the Connector .
6. Aligning the position exactly, mount the Holder L together with Spring Motor to the
Cassette Assy .
7. Secure the Holder L to the Cassette Assy with two screws.
8. Mount the Cassette Assy to the printer (RRP 2.1.1).