Removal
1. Remove the Cover Assy Front (RRP 1.1.8).
2. Remove the Cover Front L/H (RRP 1.1.10).
3. Remove the Cover Assy Rear (RRP 1.2.3).
4. Remove the Cover Assy Top (RRP 1.1.4).
In the following steps, take care not to damage the Actuator Full Stack (PL7.1.2).
5. Raising upward the left end of Eliminator Assy Exit from the left mounting position of the
Chute Assy Exit , remove it from the printer.
6. Draw the right end of Eliminator Assy Exit from the right mounting position of the Chute
Assy Exit .
Replacement
In the following steps, take care not to damage the Actuator Full Stack (PL7.1.3).
1. Insert the right end of Eliminator Assy Exit into the right mounting position of the Chute
Assy Exit from the printer.
2. Insert the left end of Eliminator Assy Exit into the left mounting position of the Chute
Assy Exit .
3. Mount the Cover Assy Top (RRP 1.1.4).
4. Mount the Cover Assy Rear (RRP 1.2.3).
5. Mount the Cover Front L/H (RRP 1.1.10).
6. Mount the Cover Assy Front (RRP 1.1.8).
OKI B6100 Laser Printer - Base Engine Technical Manual
Version 1.0
RRP 7.1.1 Eliminator Assy Exit (PL7.1.1) continued