Removal
1. Open the Cover Assy Front (PL1.1.9).
In the following steps, take care not to drop and then damage the Cover Assy
Front .
2. Remove the hook of the Spring Front (PL 1.1.25) hangs the Joint Spring(PL 1.1.24) on the
main unit from the hole of the unit.
3. Move the tip of the Stopper Cover (PL 1.1.14)from the right side of the unit to the left
side ,and then remove it from the Cover Assy Front.
4. Remove the KL clip that secures the left bearing bore of Cover Assy Front to the left stud
of the printer.
5. From the Cover Right (PL1.1.8), remove the Stopper Cover that secures the Cover Assy Front
to the printer.
6. Sliding the Cover Assy Front to the right from the printer, release the left and right
bearing bores of Cover Assy Front from the left and right studs, then remove the Cover Assy
Front .
Replacement
In the following steps, take care not to drop and then damage the Cover Assy
Front .
1. Aligning the left and right bearing bores of Cover Assy Front with the left and right studs
of the opprinter, mount the Cover Assy Front on the printer.
2. Fasten the tip of the Stopper Cover(PL 1.1.14) on the Cover Assy Front by a screw.
3. Set the tip of the Stopper Cover (PL 1.14)to the setting position placed right side of the
unit with the Joint Spring(PL 1.1.24)and the Spring Front (PL 1.1.25).
4. Hang the hook of the Spring Front on the hole placed the right side of the unit.
5. Secure the left bearing bore of Cover Assy Front to the left stud of printer with the KL
clip.
6. Close the Cover Assy Front .