Sensor Assy Cru Failure - Oki B6100 Technical Manual

Base engine
Hide thumbs Also See for B6100:
Table of Contents

Advertisement

Secondary FIPs

6.10 Sensor Assy CRU Failure

Step
1
INITIAL ANALYSIS
Inspect the following components.
• Sensor Assy CRU (PL8.1.6)
• PWBA HKB PS (PL10.1.17)
• CRU (PL8.1.1)
• PWBA HKB26 MCU (PL10.1.13)
• Harness Assy CRU SNS (J25-J251) (PL8.1.2)
Are they compatible with your printer version, correctly
installed, not damaged, deformed, or contaminated?
2
CRU (PL8.1.1) ANALYSIS
Does the tab on the CRU actuate the Sensor Assy CRU?
3
SENSOR ASSY CRU (PL8.1.6) ANALYSIS
Disconnect P/J25 on the PWBA HKB26 MCU.
Cheat the Switch Assy I/L Front (PL10.1.12).
Remove the CRU.
Is there some amount of resistance measured between
J25-2 and J25-1?
Reinstall the CRU.
Is there continuity (0Ω) between J25-2 and J25-1?
4
Harness Assy FS SNR (J30-J301) (PL7.1.16) ANALYSIS
Is there continuity (0Ω) between all wires on J30 and
J301?
6-16
Actions and Questions
OKI B6100 Laser Printer - Base Engine Technical Manual
Yes
No
Go to step 2
Replace the
problem com-
ponents
Go to step 3
Replace the
CRU
Go to step 4
Replace the
Sensor Assy
CRU
(RRP8.1.4)
Go to 6.1
Replace the
PWBA HKB
Harness Assy
PS Failure
FS SNR (J30-
(+5VDC)
-J301)
Version 1.0