interval

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
interval minutes;
[edit poe interface (all | interface-name) telemetries]
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Modify the interval at which data is collected when you are monitoring the power
consumption of a PoE interface.
minutes
—Frequency of data collection.
Range: 1 through 30
Default: 5
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.
Example: Configuring PoE Interfaces with Different Priorities on an EX Series Switch
on page 3309
Configuring PoE (CLI Procedure) on page 3315
Configuring PoE (J-Web Procedure) on page 3317