interface ge-0/0/3 {
priority high;
telemetries;
}
interface ge-0/0/4 {
priority high;
telemetries;
}
}
To verify that PoE interfaces have been created and are operational, perform the following
tasks:
Verifying That the PoE Interfaces Have Been Created with the Correct
Priorities on page 3313
Verifying That the PoE Interfaces Have Been Created with the Correct Priorities
Verify that the PoE interfaces on the switch are now set to the correct priority settings.
List all the PoE interfaces configured on the switch:
user@switch> show poe interface
Interface Admin status Oper status Max power Priority Power consumption Class
ge-0/0/0 Enabled
ON
ge-0/0/1 Enabled
ON
ge-0/0/2 Enabled
ON
ge-0/0/3 Enabled
ON
ge-0/0/4 Enabled
ON
ge-0/0/5 Enabled
ON
ge-0/0/6 Enabled
ON
ge-0/0/7 Enabled
ON
The
command lists PoE interfaces configured on the switch, with
show poe interface
their status, priority, power consumption, and class. This output shows that eight PoE
interfaces are enabled. Interfaces
. The remaining PoE interfaces are configured with the default priority value of
high
Example: Configuring PoE Interfaces on an EX Series Switch on page 3307
Configuring PoE (CLI Procedure) on page 3315
Troubleshooting PoE Interfaces on page 3325
Chapter 115: Examples: PoE Configuration
15.4W
Low
7.9W
15.4W
High
4.8W
15.4W
High
4.8W
15.4W
High
3.3W
15.4W
High
4.7W
15.4W
Low
3.2W
15.4W
Low
3.3W
15.4W
Low
3.3W
through
ge-0/0/1
ge-0/0/4
0
0
0
2
2
2
2
2
are configured as priority
.
low
3313

Advertisement

Table of Contents
loading