Juniper JUNOS OS 10.3 - SOFTWARE Manual page 3679

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Purpose
Action
Meaning
Purpose
Action
Copyright © 2010, Juniper Networks, Inc.
udp-port 5600;
sample-rate 1000;
collector 10.204.32.46;
interfaces ge-0/0/0.0;
Verification
To confirm that the configuration is correct, perform these tasks:
Verifying That sFlow Technology Has Been Configured Properly on page 3583
Verifying That sFlow Technology Is Enabled on the Intended Interface on page 3583
Verifying the sFlow Collector Configuration on page 3584
Verifying That sFlow Technology Has Been Configured Properly
Verify that sFlow technology has been configured properly.
Use the
command:
show sflow
user@switch> show sflow
sFlow
: Enabled
Sample limit
: 300 packets/second
Polling interval : 20 seconds
Sample rate
: 1:1000
Agent ID
: 10.204.96.222
NOTE: The sample limit cannot be configured and is set to 300
packets/second.
The output shows that sFlow technology is enabled and specifies the values for the
sample rate, sample limit, and polling interval.
Verifying That sFlow Technology Is Enabled on the Intended Interface
Verify that sFlow technology is enabled on interfaces and display the sampling
parameters.
Use the
show sflow interface
user@switch> show sflow interface
Interface
Status
Sample rate
ge-0/0/0.0
Enabled
1000
NOTE: The sample limit cannot be configured and is set to 300
packets/second.
Chapter 128: sFlow Monitoring Technology
command:
Adapted sample rate
16000
Polling-interval
20
3583

Advertisement

Table of Contents
loading

Table of Contents