Juniper JUNOS OS 10.3 - SOFTWARE Manual page 3863

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Results
Purpose
Action
Copyright © 2010, Juniper Networks, Inc.
[edit protocols oam ethernet connectivity-fault-management]
user@switch2# set maintenance-domain private level 0
Create a maintenance association:
3.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private]
user@switch2# set maintenance-association private-ma
Enable the continuity check protocol and specify the continuity check hold interval:
4.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private maintenance-association private-ma]
user@switch2# set continuity-check hold-interval 1s
Configure the maintenance association end point (MEP)
5.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private maintenance-association private-ma]
user@switch2# set mep 100 interface ge-0/2/5 auto-discovery direction down
Check the results of the configuration.
[edit]
user@switch2# show
protocols {
oam {
ethernet {
connectivity-fault-management {
maintenance-domain private {
level 0;
maintenance-association private-ma {
continuity-check {
interval 1s;
}
mep 100 {
interface ge-0/2/5;
auto-discovery;
direction down;
}
}
}
}
}
Verification
To confirm that the configuration is working properly, perform these tasks:
Verifying That OAM CFM Has Been Configured Properly on page 3767
Verifying That OAM CFM Has Been Configured Properly
Verify that OAM CFM has been configured properly.
Use the show oam ethernet connectivity-fault-management interfaces detail command:
user@switch1# show oam ethernet connectivity-fault-management interfaces detail
Chapter 132: Ethernet OAM Connectivity Fault Management
3767

Advertisement

Table of Contents
loading

Table of Contents