Juniper JUNOS OS 10.3 - SOFTWARE Manual page 3805

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Table 495: Performance Probe Tests Configuration Fields (continued)
Field
Destination Interface
Maximum Probe Thresholds
Successive Lost Probes
Lost Probes
Round Trip Time
Jitter
Standard Deviation
Egress Time
Ingress Time
Jitter Egress Time
Jitter Ingress Time
Copyright © 2010, Juniper Networks, Inc.
Function
Enables hardware timestamp on the
specified interface.
Sets the number of probes that can be
lost successively, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the number of probes that can be
lost , if exceeded, triggers a probe failure
and generates a system log message.
Sets the round-trip time (in
microseconds), from the switch to the
remote server, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the jitter (in microseconds), if
exceeded, triggers a probe failure and
generates a system log message.
Sets the maximum allowable standard
deviation (in microseconds), if exceeded,
triggers a probe failure and generates a
system log message.
Sets the one-way time (in
microseconds), from the switch to the
remote server, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the one-way time (in
microseconds), from the remote server
to the switch, if exceeded, triggers a
probe failure and generates a system log
message.
Sets the outbound-time jitter (in
microseconds), if exceeded triggers a
probe failure and generates a system log
message.
Sets the inbound-time jitter (in
microseconds), if exceeded, triggers a
probe failure and generates a system log
message.
Chapter 130: Real-Time Performance Monitoring (RPM)
Your Action
Select an interface from the list.
Type a number from 0 through 15.
Type a number from 0 through 15.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000.
Type a number from 0 through
60000000 (microseconds).
Type a number from 0 through
60000000.
Type a number from 0 and 60000000.
3709