Spc System Messages - Brocade Communications Systems 8 Reference

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

SPC System Messages

SPC-1001
Message
<timestamp>, [SPC-1001], <sequence-number>,, INFO, <system-name>, <slot number
containing Encryption Engine>, Cryptographic operation enabled.
Probable Cause
Indicates the cryptographic operation is enabled on an encryption engine.
Recommended
No action is required.
Action
Severity
INFO
SPC-1002
Message
<timestamp>, [SPC-1002], <sequence-number>,, INFO, <system-name>, <slot number
containing Encryption Engine>, Cryptographic operation disabled.
Probable Cause
Indicates the cryptographic operation is disabled on an encryption engine.
Recommended
No action is required.
Action
Severity
INFO
SPC-1003
Message
<timestamp>, [SPC-1003], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, Security Processor faulted.
Probable Cause
Indicates the security processor is faulted because of an internal error. Cryptographic operations
are affected.
Recommended
For a bladed system, perform slotpoweroff and slotpoweron commands on the blade to recover the
Action
system. For a non-bladed system, perform a fastboot command on the switch to recover the
system.
Severity
ERROR
Fabric OS Message Reference
53-1001767-01
Chapter
93
571

Advertisement

Table of Contents
loading

Table of Contents