40
FSS-1004
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1004
Message
<timestamp>, [FSS-1004], <sequence-number>, SLOT cp-slot-number | CHASSIS, ERROR,
<system-name>, Memory shortage
Probable Cause
Indicates that the system ran out of memory.
Recommended
Run the memShow command to view memory usage.
Action
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity
ERROR
FSS-1005
Message
<timestamp>, [FSS-1005], <sequence-number>, SLOT cp-slot-number | CHASSIS,
WARNING, <system-name>, FSS read failure
Probable Cause
Indicates that the read system call to the Fabric OS state synchronization (FSS) device failed.
Recommended
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
Action
the supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1006
Message
<timestamp>, [FSS-1006], <sequence-number>, SLOT cp-slot-number | CHASSIS,
WARNING, <system-name>, No FSS message available
Probable Cause
Indicates that data is not available on the Fabric OS state synchronization (FSS) device.
Recommended
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
Action
the supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1007
Message
<timestamp>, [FSS-1007], <sequence-number>, SLOT cp-slot-number | CHASSIS,
CRITICAL, <system-name>,
282
<component name>
: Faulty Ethernet connection.
Fabric OS Message Reference