Brocade Communications Systems 8 Reference page 726

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

108
XTUN-1004
Probable Cause
Indicates a message transmission failure.
Recommended
If there was an unexpected job failure associated with this event, contact your customer support for
Action
assistance.
Severity
ERROR
XTUN-1004
Message
<timestamp>, [XTUN-1004], <sequence-number>,, ERROR, <system-name>, Exchange
aborted:I/T/L:<FC Initiator ID> <FC Target ID> <FCP Logical Unit Number>.
Probable Cause
Indicates that the FCP exchange has been aborted by the Initiator.
Recommended
If there was an unexpected job failure associated with this event, contact your customer support for
Action
assistance.
Severity
ERROR
XTUN-1998
Message
<timestamp>, [XTUN-1998], <sequence-number>,, INFO, <system-name>, FTRACE buffer
<FTRACE Trace Buffer Number> has been cleared.
Probable Cause
Indicates that a CLI command caused the trace buffer to be put back into the FTRACE free pool.
Recommended
No action is required.
Action
Severity
INFO
XTUN-1999
Message
<timestamp>, [XTUN-1999], <sequence-number>,, WARNING, <system-name>, FTRACE
buffer <FTRACE Trace Buffer Number> has been triggered.
Probable Cause
Indicates that a programmed trigger event has been detected.
Recommended
If there was an unexpected job failure associated with this event, contact your customer support for
Action
assistance.
Severity
WARNING
XTUN-2000
Message
<timestamp>, [XTUN-2000], <sequence-number>,, INFO, <system-name>, FCIP Tunnel
<Tunnel Number> UP.
Probable Cause
Indicates that the specified FCIP tunnel is up.
650
Fabric OS Message Reference
53-1001767-01

Advertisement

Table of Contents
loading

Table of Contents