Probable Cause
Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal
Fabric OS configuration or hardware problems on the switch.
Recommended
On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the
Action
message persists, restart or power cycle the switch. Run the systemVerification command to verify
that the switch does not have hardware problems. To run this command root access is required.
Refer to the Fabric OS Command Reference Manual for more information on this command.
If the message persists, replace the FRU.
Severity
CRITICAL
EM-1013
Message
<timestamp>, [EM-1013], <sequence-number>,, ERROR, <system-name>, Failed to
update FRU information for
Probable Cause
Indicates that the environmental monitor (EM) was unable to update the time alive or the original
equipment manufacturer (OEM) data in the memory on a field-replaceable unit (FRU).
Recommended
If you ran the fruInfoSet command, try the command again; otherwise, the update is automatically
Action
attempted again. If it continues to fail, try reseating the FRU.
If the message persists, replace the FRU.
Severity
ERROR
EM-1014
Message
<timestamp>, [EM-1014], <sequence-number>,, ERROR, <system-name>, Unable to read
sensor on <FRU Id> (<Return code>)
Probable Cause
Indicates that the environmental monitor was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Try reseating the FRU. If the message persists, replace the FRU.
Action
Severity
ERROR
EM-1015
Message
<timestamp>, [EM-1015], <sequence-number>,, WARNING, <system-name>, Warm recovery
failed (
Probable Cause
Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the
Action
problem.