Severity
ERROR
SEC-1078
Message
<timestamp>, [SEC-1078], <sequence-number>,, ERROR, <system-name>, No new data to
abort.
Probable Cause
Indicates there are no new changes in the defined security policy database that can be aborted.
Recommended
Verify the security event was planned. Verify if there were really any changes to the defined policy
Action
database that can be aborted.
Severity
ERROR
SEC-1079
Message
<timestamp>, [SEC-1079], <sequence-number>,, ERROR, <system-name>, The policy
name <policy name> is invalid.
Probable Cause
Indicates the policy name entered in the secPolicyCreate|Activate|Add|Delete command was
invalid.
Recommended
Run the command again using a valid policy name.
Action
Severity
ERROR
SEC-1080
Message
<timestamp>, [SEC-1080], <sequence-number>,, ERROR, <system-name>, Operation
denied. Please, use secModeEnable command.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
SEC-1081
Message
<timestamp>, [SEC-1081], <sequence-number>,, ERROR, <system-name>, Entered a name
for a DCC policy ID that was not unique.